AG Industries CPAP Heated Tubing For Plastiflex Rainout Control System
Earn Loyalty Points
+48Buy more to unlock extra rewards!
Description
The AG Industries CPAP Heated Tubing for Plastiflex Rainout Control System (Model ROC2300) is a specialized medical device designed to prevent condensation and rainout in humidified CPAP and BiPAP therapy. This heated tubing system represents an effective solution for patients who experience water accumulation in their breathing tubes, particularly in cooler environments or during highly humidified therapy sessions.
Key Features and Benefits
- Embedded Copper Heating Technology: The tubing contains copper heating wires integrated into the tube walls, providing uniform warmth along the entire 6-foot length. This prevents temperature drops that cause condensation regardless of room temperature variations.
- Universal Compatibility: Works with all humidified CPAP and BiPAP machines that use standard 22mm tubing connectors, making it an ideal retrofit solution for existing equipment.
- Medical-Grade Power Supply: Includes a dedicated switching power adapter with plug-and-play simplicity. The power supply operates on standard household voltage (110-220V AC, 50-60 Hz) and delivers safe, regulated power to the heating elements.
- Optimal Humidification Control: By preventing rainout, the system allows users to set humidifier levels according to clinical recommendations without worrying about condensation issues. This enhances therapy effectiveness and patient comfort.
- Easy Installation and Use: Simply connect the power supply to the tubing connector, attach the humidifier-end cuff to your machine, and connect the mask-end cuff to your mask. The system is ready to use with no complex setup required.
What Is Rainout and Why It Matters
Rainout occurs when humidified air from your CPAP or BiPAP machine cools as it travels through the tubing, causing the water vapor to condense into liquid droplets. This condensation can lead to gurgling sounds, water in the mask, therapy interruptions, and reduced comfort during sleep. The Hybernite system eliminates these issues by maintaining consistent tubing temperature throughout therapy delivery.
Clinical Specifications
The Hybernite tubing measures 6 feet in length with a 19mm internal diameter, matching standard CPAP tubing dimensions. The system maintains flow resistance of 0.1 kPa or less at 60 liters per minute, ensuring minimal impact on therapy delivery. The tubing is latex-free and complies with medical device standards including ISO 5367:2000, ISO 8185:2007, and EN IEC 60601-1 certification.
Proper Care and Maintenance
Weekly cleaning is recommended to maintain optimal performance. Disconnect the tubing from both the humidifier and mask, then wash it in slightly warm, mild soapy water. Rinse thoroughly with clean water and allow to air dry completely with both cuffs hanging downward. The tubing should be replaced every 6 to 12 months or immediately if damage is detected. The power supply carries a one-year warranty, while the tubing includes a 30-day warranty.
Intended Use and Safety Considerations
The Hybernite Rainout Control System is indicated for noninvasive ventilation in adult patients requiring positive airway pressure therapy in home or sleep laboratory settings. It can be used with supplemental oxygen when necessary. Do not use the system when room temperature exceeds 30°C (86°F) to avoid elevated airway temperatures. Always use with humidification to maintain appropriate air temperature and prevent airway irritation.
Who Can Benefit
This system is particularly beneficial for patients who live in cold or humid climates, use high humidifier settings for comfort, or have experienced condensation issues with standard tubing. It provides a cost-effective alternative to purchasing new CPAP equipment with integrated heated tubing, making it accessible for most users with existing machines.
Specifications
| Specification | Value |
| Manufacturer | AG Industries |
| Brand | AG Industries / Plastiflex Hybernite |
| Model Number (MPN) | ROC2300 |
| Product Type | CPAP Heated Tubing Rainout Control System |
| Tubing Length | 6 feet (1830 mm) |
| Internal Diameter | 19 mm (3/4 inch) |
| Cuff Size | 22mm standard cuffs |
| Tubing Color | Grey |
| Contents | Hybernite Heated Hose and Medical-Grade Power Supply with Switching Power Adapter |
| Power Supply Input | 110-220V AC, 50-60 Hz |
| Power Supply Type | Switching Power Adapter (Plug-and-Play) |
| Flow Resistance | Less than or equal to 0.1 kPa at 60 L/min |
| Operating Temperature Range | 5°C to 30°C (41°F to 86°F) |
| Storage Temperature Range | -20°C to +60°C (-4°F to 120°F) |
| Relative Humidity (Operating) | 5% to 95% |
| Relative Humidity (Storage) | 5% to 95% |
| Materials | Tubing with embedded copper heating wires; latex-free |
| Compliance Standards | ISO 5367:2000, ISO 8185:2007, EN IEC 60601-1 (Type B Applied Part) |
| Water Resistance Rating | IPx3 |
| Tubing Replacement Schedule | Every 6 to 12 months or as recommended by physician/respiratory therapist |
| Power Supply Warranty | 1 Year |
| Tubing Warranty | 30 Days |
| HCPCS Code | A4604 (Heated Tubing) |
| GTIN/UPC | 05404013000098 |
| Compatibility | All humidified CPAP and BiPAP machines with standard 22mm tubing. Not compatible with slim 15mm tubing or pressure sensor tubing. Not recommended for Respironics PR System One 50 Series with software earlier than v1.24. |
| Intended Use | Prevents condensation and rainout in humidified air delivery for patients requiring positive airway pressure or mask ventilation. For adult patients in home or sleep-lab settings. For noninvasive ventilation. |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
FAQs
A: The Hybernite system prevents condensation buildup and rainout in your CPAP or BiPAP tubing. Built-in copper wires heat the tube, maintaining consistent temperature throughout its length. This reduces moisture from forming inside the hose, which commonly occurs when cooler room air causes humidified air to condense. By eliminating rainout, you can enjoy quieter, more comfortable sleep therapy.
A: The Hybernite system is designed to work with most humidified CPAP and BiPAP machines that use standard 22mm tubing. However, it is not compatible with machines requiring slim 15mm tubing or pressure sensor tubing. If you have a Respironics PR System One 50 Series, confirm your software version is 1.24 or later. For specific compatibility questions about your machine, contact your equipment provider.
A: Not necessarily. Machines with integrated heated tubing typically manage condensation effectively. However, some users prefer the additional heating provided by the Hybernite system, especially in colder climates. If you experience rainout even with your machine's standard heating, the Hybernite system may help improve your therapy comfort.
A: The Hybernite system operates at a fixed temperature and does not have variable heat control. The heating level is designed to be appropriate for most users under typical operating conditions. If the tubing feels too warm or cool for your preference, consult your respiratory therapist for guidance on humidifier settings or alternative solutions.
A: Clean the tubing weekly by disconnecting it from both your humidifier and mask. Wash it gently in slightly warm, mild soapy water, then rinse thoroughly with clean water. Allow the tubing to hang with both cuffs pointing downward and air dry completely before reconnecting. Do not use harsh soaps, solvents, or alcohols; avoid dishwashers; and never attempt to dry it with ovens, microwaves, or fans.
A: AG Industries recommends replacing the heated tubing every 6 to 12 months, or sooner if you notice damage such as holes, kinks, tears, or exposed wiring. Check your tubing regularly, and replace it immediately if any defects appear or if it stops working properly. Your respiratory therapist or physician may recommend a specific replacement schedule based on your therapy needs.
Description
The AG Industries CPAP Heated Tubing for Plastiflex Rainout Control System (Model ROC2300) is a specialized medical device designed to prevent condensation and rainout in humidified CPAP and BiPAP therapy. This heated tubing system represents an effective solution for patients who experience water accumulation in their breathing tubes, particularly in cooler environments or during highly humidified therapy sessions.
Key Features and Benefits
- Embedded Copper Heating Technology: The tubing contains copper heating wires integrated into the tube walls, providing uniform warmth along the entire 6-foot length. This prevents temperature drops that cause condensation regardless of room temperature variations.
- Universal Compatibility: Works with all humidified CPAP and BiPAP machines that use standard 22mm tubing connectors, making it an ideal retrofit solution for existing equipment.
- Medical-Grade Power Supply: Includes a dedicated switching power adapter with plug-and-play simplicity. The power supply operates on standard household voltage (110-220V AC, 50-60 Hz) and delivers safe, regulated power to the heating elements.
- Optimal Humidification Control: By preventing rainout, the system allows users to set humidifier levels according to clinical recommendations without worrying about condensation issues. This enhances therapy effectiveness and patient comfort.
- Easy Installation and Use: Simply connect the power supply to the tubing connector, attach the humidifier-end cuff to your machine, and connect the mask-end cuff to your mask. The system is ready to use with no complex setup required.
What Is Rainout and Why It Matters
Rainout occurs when humidified air from your CPAP or BiPAP machine cools as it travels through the tubing, causing the water vapor to condense into liquid droplets. This condensation can lead to gurgling sounds, water in the mask, therapy interruptions, and reduced comfort during sleep. The Hybernite system eliminates these issues by maintaining consistent tubing temperature throughout therapy delivery.
Clinical Specifications
The Hybernite tubing measures 6 feet in length with a 19mm internal diameter, matching standard CPAP tubing dimensions. The system maintains flow resistance of 0.1 kPa or less at 60 liters per minute, ensuring minimal impact on therapy delivery. The tubing is latex-free and complies with medical device standards including ISO 5367:2000, ISO 8185:2007, and EN IEC 60601-1 certification.
Proper Care and Maintenance
Weekly cleaning is recommended to maintain optimal performance. Disconnect the tubing from both the humidifier and mask, then wash it in slightly warm, mild soapy water. Rinse thoroughly with clean water and allow to air dry completely with both cuffs hanging downward. The tubing should be replaced every 6 to 12 months or immediately if damage is detected. The power supply carries a one-year warranty, while the tubing includes a 30-day warranty.
Intended Use and Safety Considerations
The Hybernite Rainout Control System is indicated for noninvasive ventilation in adult patients requiring positive airway pressure therapy in home or sleep laboratory settings. It can be used with supplemental oxygen when necessary. Do not use the system when room temperature exceeds 30°C (86°F) to avoid elevated airway temperatures. Always use with humidification to maintain appropriate air temperature and prevent airway irritation.
Who Can Benefit
This system is particularly beneficial for patients who live in cold or humid climates, use high humidifier settings for comfort, or have experienced condensation issues with standard tubing. It provides a cost-effective alternative to purchasing new CPAP equipment with integrated heated tubing, making it accessible for most users with existing machines.
Specifications
| Specification | Value |
| Manufacturer | AG Industries |
| Brand | AG Industries / Plastiflex Hybernite |
| Model Number (MPN) | ROC2300 |
| Product Type | CPAP Heated Tubing Rainout Control System |
| Tubing Length | 6 feet (1830 mm) |
| Internal Diameter | 19 mm (3/4 inch) |
| Cuff Size | 22mm standard cuffs |
| Tubing Color | Grey |
| Contents | Hybernite Heated Hose and Medical-Grade Power Supply with Switching Power Adapter |
| Power Supply Input | 110-220V AC, 50-60 Hz |
| Power Supply Type | Switching Power Adapter (Plug-and-Play) |
| Flow Resistance | Less than or equal to 0.1 kPa at 60 L/min |
| Operating Temperature Range | 5°C to 30°C (41°F to 86°F) |
| Storage Temperature Range | -20°C to +60°C (-4°F to 120°F) |
| Relative Humidity (Operating) | 5% to 95% |
| Relative Humidity (Storage) | 5% to 95% |
| Materials | Tubing with embedded copper heating wires; latex-free |
| Compliance Standards | ISO 5367:2000, ISO 8185:2007, EN IEC 60601-1 (Type B Applied Part) |
| Water Resistance Rating | IPx3 |
| Tubing Replacement Schedule | Every 6 to 12 months or as recommended by physician/respiratory therapist |
| Power Supply Warranty | 1 Year |
| Tubing Warranty | 30 Days |
| HCPCS Code | A4604 (Heated Tubing) |
| GTIN/UPC | 05404013000098 |
| Compatibility | All humidified CPAP and BiPAP machines with standard 22mm tubing. Not compatible with slim 15mm tubing or pressure sensor tubing. Not recommended for Respironics PR System One 50 Series with software earlier than v1.24. |
| Intended Use | Prevents condensation and rainout in humidified air delivery for patients requiring positive airway pressure or mask ventilation. For adult patients in home or sleep-lab settings. For noninvasive ventilation. |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
FAQs
A: The Hybernite system prevents condensation buildup and rainout in your CPAP or BiPAP tubing. Built-in copper wires heat the tube, maintaining consistent temperature throughout its length. This reduces moisture from forming inside the hose, which commonly occurs when cooler room air causes humidified air to condense. By eliminating rainout, you can enjoy quieter, more comfortable sleep therapy.
A: The Hybernite system is designed to work with most humidified CPAP and BiPAP machines that use standard 22mm tubing. However, it is not compatible with machines requiring slim 15mm tubing or pressure sensor tubing. If you have a Respironics PR System One 50 Series, confirm your software version is 1.24 or later. For specific compatibility questions about your machine, contact your equipment provider.
A: Not necessarily. Machines with integrated heated tubing typically manage condensation effectively. However, some users prefer the additional heating provided by the Hybernite system, especially in colder climates. If you experience rainout even with your machine's standard heating, the Hybernite system may help improve your therapy comfort.
A: The Hybernite system operates at a fixed temperature and does not have variable heat control. The heating level is designed to be appropriate for most users under typical operating conditions. If the tubing feels too warm or cool for your preference, consult your respiratory therapist for guidance on humidifier settings or alternative solutions.
A: Clean the tubing weekly by disconnecting it from both your humidifier and mask. Wash it gently in slightly warm, mild soapy water, then rinse thoroughly with clean water. Allow the tubing to hang with both cuffs pointing downward and air dry completely before reconnecting. Do not use harsh soaps, solvents, or alcohols; avoid dishwashers; and never attempt to dry it with ovens, microwaves, or fans.
A: AG Industries recommends replacing the heated tubing every 6 to 12 months, or sooner if you notice damage such as holes, kinks, tears, or exposed wiring. Check your tubing regularly, and replace it immediately if any defects appear or if it stops working properly. Your respiratory therapist or physician may recommend a specific replacement schedule based on your therapy needs.