AMT MiniONE G-JET Dual ENFit Y-Port Extension Set is Compatible with Mic-Key device but Non-compatible with MINI Classic Buttons.
Features
Feed Sets are provided sterile.
Helps caregiver avoid waking patient.
Feeding port and feedset connectors "Glow Green" in the dark.
The latest innovation from AMT to increase patient comfort while improving patient outcomes.
Feeding with Jejunal (Glow Green) Feed Set
Attach the Jejunal feeding set by lining up the dark line on the feed set or venting set with the dark line on the Jejunal feeding port and rotate 3/4 clockwise to lock into place, until you meet resistance. Do not rotate any further as you will cause damage to the AMT G-Jet.
The feeding set need to be cleaned after each use by rinsing with mild soapy water and re-rinse thoroughly with water.
After washing, allow them to air dry.
Feeding set can be used for up to 2 weeks providing they are adequately cleaned in between usage (follow directions as per local guidelines)Continuous feeds into the Jejunum must be given via a pump, the tube must be flushed at least 3 times a day to prevent any blockage.
If feeds are being given, the tube must be flushed before and after feeds to prevent blocking.
The patient should ideally be positioned at a minimum of 30 degrees for feeds.
What is ENFit? The International Organization for Standardization (ISO) has created a new standard design for enteral connectors, termed the "ENFit Connector." These new ENFit Connectors are intended to improve patient safety and to decrease the risk of medical device misconnections. This new connector has been designed to be incompatible with Luer adapters, which are commonly used in IV applications. The ENFit connector will look & secure very similar to a Luer threaded lock system, although the design is larger and thus, incompatible with Luers.
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.