BD Angiocath Special IV Catheters offer a wide range of products designed to provide peripheral vascular access to help meet clinicians’ needs. The catheters are made with FEP material with a clear flash chamber to help make blood flashback easily identifiable.
Features
Made with a radiopaque FEP material that provides x-ray detectability.
BD Angiocath Special IV Catheters help offer a wide range of gauges and lengths from 10–16 G in multiple length sizes.
Model No:
Catheter Length
Color Code
Flow Rate
Gauge
Tubing Diameter
382287
3 Inch
Tan
609 mL / min
10 Gauge
2.642 to 2.743 mm ID
382277
3 Inch
Light Blue
449 mL / min
12 Gauge
2.235 to 2.337 mm ID
382269
5-1/4 Inch
Orange
219 mL / min
14 Gauge
1.529 to 1.646 mm ID
382268
3-1/4 Inch
Orange
249 mL / min
14 Gauge
1.529 to 1.646 mm ID
382259
5-1/4 Inch
Gray
108 mL / min
16 Gauge
1.125 to 1.237 mm ID
382258
3-1/4 Inch
Gray
127 mL / min
16 Gauge
1.125 to 1.237 mm ID
Sizing
Brand
Angiocath
Application
Peripheral IV Catheter
Blood Control
Non Blood Control
Catheter Material
FEP Polymer
DEHP Indicator
DEHP-Free
Hub Material
Plastic Hub
Hub Type
Straight Hub
Needle Material
Stainless Steel
Number of Ports
Without Port
Pressure Rating
Not Pressure Rated
Safety Activation
Non-Safety
Safety Feature
Without Safety
Sterility
Sterile
UNSPSC Code
42221512
Usage
Disposable
Vessel Entry
Confirmation Flashback Chamber
X-Ray Compatibility
Radiopaque
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Looking for more information?
Hover Here To Zoom IN
**The images used on the website are for reference only and does not reflects the actual configuration of the product. Learn more..