BD Insyte Autoguard Vialon Shielded Peripheral IV Catheter
Starts From
Description
BD Insyte Autoguard Vialon Shielded IV Catheter with the push of a button, the needle instantly retracts, reducing the risk of accidental needlestick injuries. BD Vialon, a unique proprietary biomaterial, has been proven to enhance clinical and economic outcomes. Notched needle technology provides rapid visualization of blood return along the catheter shaft. It is an excellent choice for fragile vessels or vessels that have lost venous tone.
Features
- Reduces the risks of infiltration.
- Exhibits greater kink resistance.
- Increases the ease of penetration.
- Reduces the risks of phlebitis up to 50%.
- Reduces IV restarts due to reduced complications.
|
BD Insyte Autoguard Shielded IV Catheter with BD Vialon Biomaterial |
|||||
| Model No | Gauge | Length | Flow Rate | O.D. | I.D. |
| 381412 | 24 | 0.75" (0.7 mm x 19 mm) | 20 mL/min | .0260-.0290 | .0190-.0220 |
| 381423 | 22 | 1.00" (0.9 mm x 25 mm) | 35 mL/min | .0330-.0360 | .0240-.0270 |
| 381433 | 20 | 1.00" (1.1 mm x 25 mm) | 65 mL/min | .0410-.0440 | .0300-.0330 |
| 381434 | 20 | 1.16" (1.1 mm x 30 mm) | 60 mL/min | .0410-.0440 | .0300-.0330 |
| 381437 | 20 | 1.88" (1.1 mm x 48 mm) | 55 mL/min | .0410-.0440 | .0300-.0330 |
| 381444 | 18 | 1.16" (1.3 mm x 30 mm) | 105 mL/min | .0500-.0530 | .0370-.0400 |
| 381447 | 18 | 1.88" (1.3 mm x 48 mm) | 95 mL/min | .0500-.0530 | .0370-.0400 |
| 381454 | 16 | 1.16" (1.7 mm x 30 mm) | 220 mL/min | .0670-.0700 | .0520-.0550 |
| 381457 | 16 | 1.77" (1.7 mm x 45 mm) | 205 mL/min | .0670-.0700 | .0520-.0550 |
| 381467 | 14 | 1.75" (2.1 mm x 45 mm) | 330 mL/min | .0830-.0860 | .0665-.0705 |
Specifications
| Brand | Insyte Autoguard |
| Manufacturer | BD |
| Application | Peripheral IV Catheter |
| Blood Control | Non Blood Control |
| Catheter Material | BD Vialon |
| Hub Material | Plastic Hub |
| Hub Type | Straight Hub |
| Needle Material | Stainless Steel |
| Number of Ports | Without Port |
| Safety Activation | Push Button Safety |
| X-Ray Compatibility | Radiopaque |
| Vessel Entry Confirmation | Instaflash Needle |
| Usage | Disposable |
| Sterility | Sterile |
| Safety Feature | Shielding |
| Pressure Rating | 300 psi |
| Needle Point Style | Notched Needle |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Description
BD Insyte Autoguard Vialon Shielded IV Catheter with the push of a button, the needle instantly retracts, reducing the risk of accidental needlestick injuries. BD Vialon, a unique proprietary biomaterial, has been proven to enhance clinical and economic outcomes. Notched needle technology provides rapid visualization of blood return along the catheter shaft. It is an excellent choice for fragile vessels or vessels that have lost venous tone.
Features
- Reduces the risks of infiltration.
- Exhibits greater kink resistance.
- Increases the ease of penetration.
- Reduces the risks of phlebitis up to 50%.
- Reduces IV restarts due to reduced complications.
|
BD Insyte Autoguard Shielded IV Catheter with BD Vialon Biomaterial |
|||||
| Model No | Gauge | Length | Flow Rate | O.D. | I.D. |
| 381412 | 24 | 0.75" (0.7 mm x 19 mm) | 20 mL/min | .0260-.0290 | .0190-.0220 |
| 381423 | 22 | 1.00" (0.9 mm x 25 mm) | 35 mL/min | .0330-.0360 | .0240-.0270 |
| 381433 | 20 | 1.00" (1.1 mm x 25 mm) | 65 mL/min | .0410-.0440 | .0300-.0330 |
| 381434 | 20 | 1.16" (1.1 mm x 30 mm) | 60 mL/min | .0410-.0440 | .0300-.0330 |
| 381437 | 20 | 1.88" (1.1 mm x 48 mm) | 55 mL/min | .0410-.0440 | .0300-.0330 |
| 381444 | 18 | 1.16" (1.3 mm x 30 mm) | 105 mL/min | .0500-.0530 | .0370-.0400 |
| 381447 | 18 | 1.88" (1.3 mm x 48 mm) | 95 mL/min | .0500-.0530 | .0370-.0400 |
| 381454 | 16 | 1.16" (1.7 mm x 30 mm) | 220 mL/min | .0670-.0700 | .0520-.0550 |
| 381457 | 16 | 1.77" (1.7 mm x 45 mm) | 205 mL/min | .0670-.0700 | .0520-.0550 |
| 381467 | 14 | 1.75" (2.1 mm x 45 mm) | 330 mL/min | .0830-.0860 | .0665-.0705 |
Specifications
| Brand | Insyte Autoguard |
| Manufacturer | BD |
| Application | Peripheral IV Catheter |
| Blood Control | Non Blood Control |
| Catheter Material | BD Vialon |
| Hub Material | Plastic Hub |
| Hub Type | Straight Hub |
| Needle Material | Stainless Steel |
| Number of Ports | Without Port |
| Safety Activation | Push Button Safety |
| X-Ray Compatibility | Radiopaque |
| Vessel Entry Confirmation | Instaflash Needle |
| Usage | Disposable |
| Sterility | Sterile |
| Safety Feature | Shielding |
| Pressure Rating | 300 psi |
| Needle Point Style | Notched Needle |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Starts From