BD Vacutainer PPT is a closed system allowing separation and storage of undiluted EDTA plasma in the primary blood collection tube. It is intended for the purposes of molecular diagnostic testing.
PPT is an evacuated, sterile blood collection tube that contains an inert gel and spray-dried K2EDTA anticoagulant for achieving plasma separation. When the sample-filled tube is subjected to centrifugation, the gel migrates and forms a physical barrier between the plasma and most of the cellular elements. Since the tube uses spray-dried K2EDTA as opposed to liquid additives, the plasma obtained is undiluted.
Preparation And Storage
Store unfilled tubes at 4-25ºC. Limited excursion temperatures up to 40ºC, for a cumulative time not to exceed 10 days, are acceptable.
Features
Mylar label
Volume: 5 mL
Type: Plasma Tube
Dimensions: 13 X 100 mm
Whole blood is collected and processed in a closed, sterile tube
During centrifugation, a gel barrier isolates the plasma from cellular components of the blood
The BD Vacutainer PPT Tube is designed for the one-step preparation of undiluted plasma specimens for molecular diagnostic test methods or where undiluted plasma is required
Instructions For Use
Prepare venipuncture site with an appropriate antiseptic. Use your institution’s recommended procedure for standard venipuncture technique and sample collection.
Remove needle shield.
Perform venipuncture.
Place tube in holder and push tube forward until tube stopper has been penetrated.
Release tourniquet as soon as blood appears in tube.
Wait until tube has filled to its stated volume and blood flow ceases.
Pull tube off needle inside holder.
Remove tube from holder.
After collection of whole blood in the BD PPT Tube, immediately and gently invert the BD PPT Tube 8–10 times.
After mixing, the whole blood specimen may be stored up to six (6) hours at room temperature until centrifugation.
Centrifuge BD PPT Tube in a balanced, swing-out rotor type centrifuge at room temperature at 1,100 RCF for a minimum of 10 minutes.
Note: Use of alternate centrifugation conditions may also provide acceptable performance; this should be evaluated and validated by the laboratory.
To obtain an undiluted plasma sample, remove the BD Hemogard Closure (See Instructions for Removal of BD Hemogard Closure Section) and decant plasma into a separate vessel or aliquot plasma into a separate vessel using a transfer pipette.
NOTE: When using a transfer pipette be sure NOT to disturb the gel barrier with the tip of the pipette.
Sizing
Brand
BD Vacutainer PPT
Manufacturer
BD
Additive
K2 EDTA / Separator Gel Additive
Application
Molecular Diagnostic Tube
Closure Color
Pearlesent White
Closure Type
BD Hemogard Closure
Color Code
White
Dimensions
13 X 100 mm
HCPCS
A4770
Volume
5 mL
Material
Plastic Tube
Sterility
Sterile
Tube Color
Clear Tube
Tube Material
Plastic
Type
Plasma Tube
UNSPSC Code
41104107
Warranty
The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
No returns will be accepted after 30 days from the date of shipment.
All returns are subject to a restocking fee as per manufacturers terms and conditions.
All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
Hygiene, bath and toilet items cannot be returned once opened or used.
Standard manufacturer terms and conditions apply for return policy of this product.