Corflo Nasogastric Feeding Tube with Stylet and ANTI-IV Connector, Non-Enfit

SKU:AV20-9226AIV2-MI
MPN:20-9226AIV2

Starts From

$25.97
$27.27Save $1.30
Subscribe & Save
Save 5%
$24.67$25.97
Secure transaction
Your payment information is processed securely.

Description

Corflo Nasogastric/Nasointestinal Feeding Tube with stylet and ANTI-IV Connector is designed for use with the Halyard CORTRAK 2 Enteral Access System (EAS). It enables clinicians to accurately place NG/NI feeding tubes at the bedside without requiring routine X-ray confirmation, helping reduce placement time and enhancing procedural efficiency.

Features

  • Includes a stylet to support smooth and controlled tube insertion.
  • Non-weighted design for placement flexibility and patient comfort.
  • Equipped with an ANTI-IV safety connector to help prevent misconnections.
  • Supplied without an ENFit connector to meet specific clinical compatibility needs.

Indications for Use

The Avanos Corflo Feeding Tube is designed for patients who require intermittent or continuous tube feedings through the nasogastric or nasoenteric route.

Device Lifetime

The device has been validated for use up to 30 days.

Tube Maintenance

  • Follow your institution/facility/hospital protocol or clinician’s order.
  • It is recommended that the tube be irrigated every 4 hours with up to 20 ml of water (up to 10 ml for infants or children) before and after medication administration or when feeding formula is interrupted. Warning: Vigorous syringe force should not be used to irrigate, administer liquids, or unblock the tube.
  • The feeding tube should be monitored, regularly assessed, and replaced when clinically indicated based on functionality and patient condition.

Complications

Infrequently occurring factors as a result of use or misuse of any feeding tube may include:

  • Pneumothorax, GI perforation, Aspiration, Airway obstruction, Tissue irritation or necrosis, Allergic reaction, Contamination, Delay in diagnosis, Delay or misdose of medication or nutrition, and related complications or the need for additional medical procedures.

MRI Safety Information

Non-clinical testing demonstrated that the weighted CORFLO Enteral Feeding Tubes are MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions:

  • Static magnetic field of 3-Tesla or less
  • Spatial gradient magnetic field of 720-Gauss/cm or less
  • The MR system reported a whole body averaged SAR of 3.0-W/kg (i.e., associated with a calorimetry measured value of 2.8- W/kg)

For more Information, you can refer PDF

Warnings

  • The patient should not lean forward, nor should the head and neck be extended.
  • Pre-measurement of tubing length is essential. Do not insert excess. Occlusion may result from kinking of the tube.
  • Coughing may indicate passage of the tube into the trachea. If tracheal passage is suspected, remove the tube. Absence of coughing does not confirm tube placement in the stomach. If resistance is encountered, immediately remove the tube. Notify clinician. Care should be taken if any type of endotracheal device is in place, as it may guide the feeding tube into the trachea. Misplacement of the feeding tube into the trachea or lungs may result in serious injury.
  • Tube position in the stomach must be confirmed before flushing and use.
  • Never reinsert the stylet when the tube is in the patient.
  • Vigorous syringe force should not be used to irrigate, administer liquids, or unblock the tube.

Specifications

Brand Corflo
Manufacturer Avanos Medical
Anti-IV connector Yes
Bolus Type ANTI-CLOG
ENFit Connector No
Primary Product Color Yellow
Radiopaque Yes
Radiopaque Stripe No
Tip Weight Type Non-Weighted
Application Nasogastric / Nasointestinal Feeding Tube

Warranty

  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

Return

  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.