Corflo Nasogastric-Nasointestinal Feeding Tube with Anti-IV Connector

SKU:AV20-1226AIV2-MI
MPN:20-1226AIV2

Starts From

$35.16
$36.92Save $1.76
Subscribe & Save
Save 5%
$33.40$35.16
Secure transaction
Your payment information is processed securely.
Latex Free
Latex Free

Description

Corflo Nasogastric/Nasointestinal Feeding Tube is expertly engineered to support reliable and consistent delivery of enteral nutrition for patients requiring nasogastric or nasoenteric access. This advanced tube system integrates performance-focused features such as an anti-clog bolus, clear centimeter markings, and a water-activated, lubricated tip and internal lumen that help streamline placement. Designed to match a wide range of clinical needs, these feeding tubes offer flexibility through multiple connector options, including ENFit, Universal, and Anti-IV configurations. Available in an assortment of French sizes and lengths, the polyurethane CORFLO NG/NI tubes from Avanos Medical continue to uphold a strong reputation for high-quality enteral feeding solutions, making them a trusted choice for healthcare facilities seeking durable, innovative, and patient-centric enteral nutrition products.

Features

  • CM Markings.
  • Anti-clog bolus.
  • With and without a stylet.
  • Weighted/Non-Weighted.
  • Flow-Through Stylet.Radiopaque.
  • MRI conditional once the stylet is removed.
  • ENFit, Universal, and Anti-IV proximal connectors.
  • Water Activated Lubricated Tip & Internal Lumen (stylet tubes only).

Indications: AVANOS CORFLO Feeding Tube is for patients needing intermittent or continuous nasogastric/nasoenteric feeding.

Duration of Use: Validated for up to 30 days.

Tube Maintenance

  • Follow hospital protocol or clinician orders.
  • Flush every 4 hours with ≤20 mL water (≤10 mL in infants/children) before/after medications or when feeding stops.
  • Monitor regularly; replace when clinically indicated.

Possible Complications

  • Pneumothorax, GI perforation, aspiration, airway obstruction, tissue irritation/necrosis, allergic reaction, contamination, delayed diagnosis.
  • Medication/nutrition delay or misdose; need for additional procedures.

MRI Safety

Weighted CORFLO tubes are MR Conditional:

  • Static field ≤3 Tesla
  • Spatial gradient ≤720 Gauss/cm
  • Whole-body averaged SAR ≤3.0 W/kg

Warnings

  • Avoid forward leaning or neck extension during insertion.
  • Pre-measure length; do not over-insert (risk of kinking/occlusion).
  • Coughing or resistance may indicate tracheal placement — remove the tube immediately.
  • Always confirm gastric placement before use.
  • Never reinsert the stylet while the tube is in the patient.
  • Do not use excessive syringe force.

Note: Crush medications finely and dilute thoroughly (no visible particles) to prevent clogging.

Warranty

  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

Return

  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.