Curlin 6000 CMS Ambulatory Infusion System
Product Information
Curlin 6000 CMS Ambulatory Infusion System Images
**The images on the website are for reference only and do not reflect the actual configuration of the product.** Learn more..
Curlin 6000 CMS Ambulatory Infusion System
Loyalty Points
You will earn up to 4148 points on this order

Loyalty Points
You will earn up to 4148 points on this order
Product Features and Benefits
.png)
Free Shipping
Quantity
Curlin 6000 CMS Ambulatory Infusion System Purchase Options
Auto Reorder Information
Auto Reorder Information
Product Features and Policies
Product Features and Policies
CURLIN 6000 Ambulatory Infusion Pump by Moog is uniquely designed to bring home healthcare clinicians and pharmacists more precise, accurate, and efficient infusion. With multi-therapy delivery options, a compact size, and built-in safety protocols, the CURLIN 6000 Pump is ideal for the growing home infusion therapy market.
When precision and accuracy matter most: The patented curvilinear peristaltic design of the CURLIN 6000 delivers fluid in smaller, more accurate increments than standard linear peristaltic infusion pumps (Resolution of Flow) with more precise and steady fluid delivery throughout the entire infusion duration (Continuity of Flow).
Resolution of Flow and Continuity of Flow impact how medication is delivered to patients. Understanding these attributes is essential when administering infusions to sensitive patient populations, and when infusing short half-life drugs or other drugs delivered at a low infusion rate.
Multiple Therapies. One Device: From delivering antibiotics and nutrition to highly specialized oncology medications, the CURLIN 6000 meets the majority of infusion delivery profiles through its five therapy options.
- Continuous: Delivers a constant programmed rate of infusion
- Intermittent: Delivers the infusion therapy in programmed intervals and at rates of specified amounts of infusates.
- Variable: Provides 24 specified programs of varying amounts, rates, and times of delivery.
- Total Parenteral Nutrition: Designed to allow a level rate of infusion of parenteral nutritional products with the option of tapering at the beginning and/or end of the infusion.
- Patient Controlled Analgesia: Designed for therapies requiring a continuous rate of infusion, patient-controlled demand boluses, or both.
An Innovative Multi-Therapy Infusion Device in a Small, Portable Package
- Easy-to-Use: Programming simplicity matched with menu-driven protocols and context-sensitive HELP screens result in an extremely easy-to-use infusion device.
- Flexible: Multiple therapy flexibility provides the ability to meet specific workflow needs. Access to actionable reports and detailed infusion information enhances device performance.
- Reduces Total Cost: The simplicity of operation, reliable technology, low administration PVC set costs, and availability of extensive training options may effectively reduce your total cost of pump ownership. Learn more about determining your total cost of pump ownership.
- Safe: In addition to its reliable performance and built-in safety features, the CURLIN 6000 can be used with the Protocol Library Safety System (PLSS), providing the ability to upload pre-validated drug protocols or patient prescriptions, and eliminating the risk of unintended infusion.
Enhance safety and control with the Protocol Library Safety System: CURLIN’s Protocol Library Safety System (PLSS) is designed to shorten programming time and reduce opportunities for user error. PLSS allows you to create patient-specific protocols, or develop a drug library for all your patients.
Note:
- PLSS is required to achieve IV flow rates greater than 9.9 mL/hr
- If used with syringes, this accuracy may vary due to the physical properties of the syringe used
Sizing
Sizing
Mechanism: | Curvilinear peristaltic pump action |
Therapies Supported: | Continuous, PCA, TPN, Intermittent, Variable |
Size: | 5.1” (13 cm) x 4.0” (10.2 cm) x 2.5” (6.4 cm)
18.1 ounces (513 grams) |
Display: | 2.5” (6.3 cm) x 1.2” (3.1 cm) Continuous backlit with AC |
Accuracy: | +/- 5%* |
Flow Rates: | 0.1 – 400 mL/hr, increments of 0.1 mL/hr |
Flow Rates (PCA):** | 0.1 – 50 mL/hr IV, 25 mL/hr EPI, 5 mL/hr SQ Max |
Volume Limits: | 1.0 – 9,999 mL, increments of 0.1 mL |
KVO Rates: | 0.0 – 10 mL/hr (not available in PCA mode) |
Power Sources: | 2 “C” alkaline batteries, AC, external rechargeable battery pack |
Units: | mL, mg, mcg |
Bolus Volume: | 0.1 – 9.9 mL |
Max # of Boluses: | 15/hr |
Patient Bolus: | 0.1 – 9.9 mL/dose IV, 0.1 – 25 mL/dose EPI, 0.1 – 5 mL/dose SQ |
Bolus Lockout: | 1 – 60 minutes, increments of 1 minute |
Operating Time:
(with fully charged batteries) |
Nominal 10 hrs. at 400 mL/hr 4 Nominal 30 hrs. at 125 mL/hr 4 Nominal 85 hrs. at 2 mL/hr |
Alarms: | Air-in-line, high upstream pressure, occlusion upstream, occlusion downstream, door open, set not installed, unattended pump, replace set, empty battery |
Accessories: | Bolus cord, pole clamp, and external rechargeable battery pack |
Adjustable Alarm Volume: | 1 – 9 with 9 being the loudest |
Data Log: | 6,000 events, including line pressure, volume infused, time |
Additional Features: | Real-time line pressure, shift totals, on-screen hourly totals, highly visible large fonts, quick repeat feature, continuous back-light-on with AC power, titration in continuous and PCA modes, unused therapies can be locked out, four (4) access levels for security, on-line & context sensitive help screens, data interface port, printable history log |
Security: | Unused therapies can be blocked out, four access levels, different lock box sizes |
Software: | Protocol Library: multiple categories and potential for over 100 protocols |
Administration Sets: | DEHP-free set configurations, needleless injection sites, 0.22 and 1.2 micron filtered sets, yellow-striped epidural sets, sets with 150 mL integral fluid containers |
Warranty
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
CURLIN 6000 Ambulatory Infusion Pump by Moog is uniquely designed to bring home healthcare clinicians and pharmacists more precise, accurate, and efficient infusion. With multi-therapy delivery options, a compact size, and built-in safety protocols, the CURLIN 6000 Pump is ideal for the growing home infusion therapy market.
When precision and accuracy matter most: The patented curvilinear peristaltic design of the CURLIN 6000 delivers fluid in smaller, more accurate increments than standard linear peristaltic infusion pumps (Resolution of Flow) with more precise and steady fluid delivery throughout the entire infusion duration (Continuity of Flow).
Resolution of Flow and Continuity of Flow impact how medication is delivered to patients. Understanding these attributes is essential when administering infusions to sensitive patient populations, and when infusing short half-life drugs or other drugs delivered at a low infusion rate.
Multiple Therapies. One Device: From delivering antibiotics and nutrition to highly specialized oncology medications, the CURLIN 6000 meets the majority of infusion delivery profiles through its five therapy options.
- Continuous: Delivers a constant programmed rate of infusion
- Intermittent: Delivers the infusion therapy in programmed intervals and at rates of specified amounts of infusates.
- Variable: Provides 24 specified programs of varying amounts, rates, and times of delivery.
- Total Parenteral Nutrition: Designed to allow a level rate of infusion of parenteral nutritional products with the option of tapering at the beginning and/or end of the infusion.
- Patient Controlled Analgesia: Designed for therapies requiring a continuous rate of infusion, patient-controlled demand boluses, or both.
An Innovative Multi-Therapy Infusion Device in a Small, Portable Package
- Easy-to-Use: Programming simplicity matched with menu-driven protocols and context-sensitive HELP screens result in an extremely easy-to-use infusion device.
- Flexible: Multiple therapy flexibility provides the ability to meet specific workflow needs. Access to actionable reports and detailed infusion information enhances device performance.
- Reduces Total Cost: The simplicity of operation, reliable technology, low administration PVC set costs, and availability of extensive training options may effectively reduce your total cost of pump ownership. Learn more about determining your total cost of pump ownership.
- Safe: In addition to its reliable performance and built-in safety features, the CURLIN 6000 can be used with the Protocol Library Safety System (PLSS), providing the ability to upload pre-validated drug protocols or patient prescriptions, and eliminating the risk of unintended infusion.
Enhance safety and control with the Protocol Library Safety System: CURLIN’s Protocol Library Safety System (PLSS) is designed to shorten programming time and reduce opportunities for user error. PLSS allows you to create patient-specific protocols, or develop a drug library for all your patients.
Note:
- PLSS is required to achieve IV flow rates greater than 9.9 mL/hr
- If used with syringes, this accuracy may vary due to the physical properties of the syringe used
Details
Mechanism: | Curvilinear peristaltic pump action |
Therapies Supported: | Continuous, PCA, TPN, Intermittent, Variable |
Size: | 5.1” (13 cm) x 4.0” (10.2 cm) x 2.5” (6.4 cm)
18.1 ounces (513 grams) |
Display: | 2.5” (6.3 cm) x 1.2” (3.1 cm) Continuous backlit with AC |
Accuracy: | +/- 5%* |
Flow Rates: | 0.1 – 400 mL/hr, increments of 0.1 mL/hr |
Flow Rates (PCA):** | 0.1 – 50 mL/hr IV, 25 mL/hr EPI, 5 mL/hr SQ Max |
Volume Limits: | 1.0 – 9,999 mL, increments of 0.1 mL |
KVO Rates: | 0.0 – 10 mL/hr (not available in PCA mode) |
Power Sources: | 2 “C” alkaline batteries, AC, external rechargeable battery pack |
Units: | mL, mg, mcg |
Bolus Volume: | 0.1 – 9.9 mL |
Max # of Boluses: | 15/hr |
Patient Bolus: | 0.1 – 9.9 mL/dose IV, 0.1 – 25 mL/dose EPI, 0.1 – 5 mL/dose SQ |
Bolus Lockout: | 1 – 60 minutes, increments of 1 minute |
Operating Time:
(with fully charged batteries) |
Nominal 10 hrs. at 400 mL/hr 4 Nominal 30 hrs. at 125 mL/hr 4 Nominal 85 hrs. at 2 mL/hr |
Alarms: | Air-in-line, high upstream pressure, occlusion upstream, occlusion downstream, door open, set not installed, unattended pump, replace set, empty battery |
Accessories: | Bolus cord, pole clamp, and external rechargeable battery pack |
Adjustable Alarm Volume: | 1 – 9 with 9 being the loudest |
Data Log: | 6,000 events, including line pressure, volume infused, time |
Additional Features: | Real-time line pressure, shift totals, on-screen hourly totals, highly visible large fonts, quick repeat feature, continuous back-light-on with AC power, titration in continuous and PCA modes, unused therapies can be locked out, four (4) access levels for security, on-line & context sensitive help screens, data interface port, printable history log |
Security: | Unused therapies can be blocked out, four access levels, different lock box sizes |
Software: | Protocol Library: multiple categories and potential for over 100 protocols |
Administration Sets: | DEHP-free set configurations, needleless injection sites, 0.22 and 1.2 micron filtered sets, yellow-striped epidural sets, sets with 150 mL integral fluid containers |
Details
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Details
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.