Intersurgical I-Gel Supraglottic Airway for Infant | Respiratory Airways
Product Information
Intersurgical I-Gel Supraglottic Airway for Infant Images
**The images on the website are for reference only and do not reflect the actual configuration of the product.** Learn more..
Intersurgical I-Gel Supraglottic Airway For Infant
Product Configuration Options
Starts From
Quantity
Product Features and Policies
Product Features and Policies
Introducing the Intersurgical I-Gel Supraglottic Airway for Infant - the perfect solution for providing optimal airway management during medical procedures. Designed with both the patient and clinician in mind, this innovative airway device offers a range of features that deliver significant benefits.
Features:
- 15 mm connector: This airway device ensures a reliable connection to any standard catheter mount or connection, allowing for smooth and seamless procedures.
- Gastric channel: With the exception of size 1, the I-Gel incorporates a gastric channel. This feature serves multiple purposes: it provides an early warning of regurgitation, allows for the passing of a nasogastric tube to empty stomach contents, and facilitates venting. This comprehensive solution ensures the safety and comfort of both the patient and clinician.
- Integral bite block: By incorporating an integral bite block, the I-Gel significantly reduces the possibility of airway channel occlusion. This ensures uninterrupted airflow and eliminates potential complications.
- Buccal cavity stabilizer: The buccal cavity stabilizer aids insertion and eliminates the potential for rotation. This simplified process allows for efficient and effective airway management.
- Epiglottic rest: The I-Gel includes an epiglottic rest, which reduces the possibility of epiglottic 'down folding' and airway obstruction. This feature ensures a clear and unobstructed airway, promoting optimal patient outcomes.
- Non-inflatable cuff: Made from a unique soft gel-like material, the non-inflatable cuff allows for ease of insertion and reduces trauma. This gentle approach enhances patient comfort and minimizes potential complications.
Benefits:
- Reliable connection: The 15 mm connector allows for a secure and reliable connection to any standard catheter mount or connection, ensuring smooth procedures and peace of mind for clinicians.
- Gastric channel for added safety: The incorporation of a gastric channel in the I-Gel provides multiple benefits, including the early detection of regurgitation, easy emptying of stomach contents, and venting. These features contribute to a safer and more efficient airway management process.
- Avoid airway occlusion: The integral bite block helps prevent airway channel occlusion, ensuring uninterrupted airflow and enhancing patient safety.
- Efficient insertion: The buccal cavity stabilizer simplifies the insertion process and eliminates the potential for rotation, allowing for efficient and effective airway management.
- Clear airway and reduced obstruction: The inclusion of an epiglottic rest in the I-Gel decreases the possibility of epiglottic 'down folding' and airway obstruction, ensuring a clear passage for optimal breathing.
- Gentle and comfortable: The non-inflatable cuff made from a soft gel-like material enables easy insertion and reduces trauma, providing a gentler experience for the patient.
Sizing
Application | Supraglottic Airway |
Color | Light Blue / Clear |
Is_Active_Vendor | Y |
Is_DSCSA | N |
Is_Discontinued | N |
Is_Medical_Device | Y |
Lot_Tracking_Flag | N |
On_Allocation | N |
Size | Size 1.5 |
Supplier_ID | 54644589 |
UNSPSC Code | 42271913 |
Usage | Single Patient Use |
User | Infant |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
Introducing the Intersurgical I-Gel Supraglottic Airway for Infant - the perfect solution for providing optimal airway management during medical procedures. Designed with both the patient and clinician in mind, this innovative airway device offers a range of features that deliver significant benefits.
Features:
- 15 mm connector: This airway device ensures a reliable connection to any standard catheter mount or connection, allowing for smooth and seamless procedures.
- Gastric channel: With the exception of size 1, the I-Gel incorporates a gastric channel. This feature serves multiple purposes: it provides an early warning of regurgitation, allows for the passing of a nasogastric tube to empty stomach contents, and facilitates venting. This comprehensive solution ensures the safety and comfort of both the patient and clinician.
- Integral bite block: By incorporating an integral bite block, the I-Gel significantly reduces the possibility of airway channel occlusion. This ensures uninterrupted airflow and eliminates potential complications.
- Buccal cavity stabilizer: The buccal cavity stabilizer aids insertion and eliminates the potential for rotation. This simplified process allows for efficient and effective airway management.
- Epiglottic rest: The I-Gel includes an epiglottic rest, which reduces the possibility of epiglottic 'down folding' and airway obstruction. This feature ensures a clear and unobstructed airway, promoting optimal patient outcomes.
- Non-inflatable cuff: Made from a unique soft gel-like material, the non-inflatable cuff allows for ease of insertion and reduces trauma. This gentle approach enhances patient comfort and minimizes potential complications.
Benefits:
- Reliable connection: The 15 mm connector allows for a secure and reliable connection to any standard catheter mount or connection, ensuring smooth procedures and peace of mind for clinicians.
- Gastric channel for added safety: The incorporation of a gastric channel in the I-Gel provides multiple benefits, including the early detection of regurgitation, easy emptying of stomach contents, and venting. These features contribute to a safer and more efficient airway management process.
- Avoid airway occlusion: The integral bite block helps prevent airway channel occlusion, ensuring uninterrupted airflow and enhancing patient safety.
- Efficient insertion: The buccal cavity stabilizer simplifies the insertion process and eliminates the potential for rotation, allowing for efficient and effective airway management.
- Clear airway and reduced obstruction: The inclusion of an epiglottic rest in the I-Gel decreases the possibility of epiglottic 'down folding' and airway obstruction, ensuring a clear passage for optimal breathing.
- Gentle and comfortable: The non-inflatable cuff made from a soft gel-like material enables easy insertion and reduces trauma, providing a gentler experience for the patient.
Application | Supraglottic Airway |
Color | Light Blue / Clear |
Is_Active_Vendor | Y |
Is_DSCSA | N |
Is_Discontinued | N |
Is_Medical_Device | Y |
Lot_Tracking_Flag | N |
On_Allocation | N |
Size | Size 1.5 |
Supplier_ID | 54644589 |
UNSPSC Code | 42271913 |
Usage | Single Patient Use |
User | Infant |
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.