


Medline One-Layer Tray with Drain Bag & 14 Fr Foley Catheter
Earn Loyalty Points
+46Buy more to unlock extra rewards!
Description
Medline One-Layer Foley catheter tray is a comprehensive closed-system catheterization solution designed for healthcare professionals in hospitals, clinics, and long-term care facilities. This pre-assembled kit combines a 14 Fr silicone-elastomer coated latex Foley catheter with a 2000 mL drain bag, delivering a complete sterile insertion system that emphasizes best practices and infection prevention.
This one-layer tray design creates an intuitive pathway through the catheterization process, minimizing contamination risk while ensuring all necessary components are organized and accessible. The silicone-elastomer coating on the latex catheter provides enhanced biocompatibility and resistance to encrustation and bacterial colonization, supporting extended catheter dwell time when clinically appropriate.
Catheter Specifications:
- French Size: 14 Fr with 10 mL balloon capacity
- Material: Silicone-elastomer coated latex for durability and biocompatibility
- Length: 16 inches (40.6 cm) standard adult sizing
- Tip Design: Straight tip with two opposing drainage eyes for optimal urine flow
- Model Type: 2-way catheter system
Drainage System Features:
- Drain Bag Capacity: 2000 mL with integrated collection chamber
- System Type: Closed sterile system to reduce contamination and infection risk
- Pre-Connection: Catheter is pre-connected to drain bag for seamless integration
- Anti-Reflux Design: Helps prevent backflow of urine into the bladder
Complete Kit Contents:
- Silicone-elastomer coated latex Foley catheter (14 Fr, 10 mL)
- 2000 mL drain bag with tubing
- Sterile vinyl examination gloves
- Water-soluble lubricating jelly for catheter insertion
- PVP swab sticks (3-pack) for patient cleansing and antiseptic preparation
- Pre-filled 10 mL sterile saline inflation syringe for balloon inflation
- Specimen collection container for urinalysis or culture
- Fenestrated sterile drape for field draping
- Underbuttocks moisture-proof drape for patient protection
- Skin prep pad (alcohol-based) for site preparation
- Foley catheter securement device to prevent migration and kinking
- Patient education card explaining catheter care and precautions
- Hand sanitizer packet for hygiene compliance
Specifications
| Catheter Included | Yes |
| Closed System | Yes |
| Coating | Silicone Elastomer |
| Drain Bag Capacity ML | 2000 ml |
| Drain Bag Included | Yes |
| Drainage Eye Type | Two Opposing Drainage Eyes |
| ERASE Cauti | Yes |
| French Size (FR) | 14 |
| Gloves | Yes |
| Length Inches | 16 " |
| Length in CM | 40.6 cm |
| Lube Jelly | Yes |
| Material | Latex |
| Model Type | 2 way |
| Patient Prep | PVP |
| Patient Type | Adult |
| Peri Care Wipe Included | No |
| Specimen Container | Yes |
| Pvp | Yes |
| Silver | No |
| Temperature Sensing | No |
| Tip Type | Straight |
| Volume ML | 10 mL |
| UNSPSC | 42142715 |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
FAQs
Frequently Asked Questions:
What is included in the Medline One-Layer Foley Catheter Tray?
This comprehensive tray comes with a 14 Fr silicone-elastomer coated latex Foley catheter pre-connected to a 2,000 mL drain bag, plus all insertion components. You'll also receive vinyl gloves, lubricating jelly, PVP swabs, a pre-filled inflation syringe, specimen container, drapes, skin prep pads, a Foley securement device, and patient education materials for a complete closed sterile system.
Who should use this catheter tray, and is it suitable for long-term use?
This product is designed for adult patients requiring urinary catheterization in healthcare settings such as hospitals, clinics, and long-term care facilities. The silicone-elastomer coating helps resist encrustation and bacterial colonization, which can support longer catheter dwell time, though insertion protocols should follow your facility's clinical guidelines.
What does the 14 Fr size mean, and is this the right size for my patient?
French (Fr) is the unit of measurement for catheter diameter. A 14 Fr catheter is a common intermediate size for adult patients. The appropriate size depends on individual patient anatomy, gender, and clinical assessment. Healthcare providers should follow their facility's protocols and clinical judgment when selecting catheter size.
Is this product latex-free, and what should I know about latex allergies?
This catheter tray contains latex material and is not suitable for patients with documented latex allergies. If your patient has a known latex sensitivity or allergy, consult your supplier for alternative catheter options that are latex-free and specify this requirement when ordering.
What makes the silicone-elastomer coating beneficial?
The silicone-elastomer coating applied both internally and externally helps resist mineral encrustation and reduce bacterial colonization on the catheter surface. This can support improved biocompatibility and potentially reduce complications related to catheter obstruction and infection when used according to clinical best practices.
What is the drain bag capacity, and how often should it be emptied?
The included drain bag holds up to 2,000 mL of urine. Drainage bags should be emptied regularly to prevent backflow and maintain proper catheter function. Your facility's protocols and the patient's specific medical needs will determine the appropriate emptying schedule, typically when the bag reaches three-quarters full.
Description
Medline One-Layer Foley catheter tray is a comprehensive closed-system catheterization solution designed for healthcare professionals in hospitals, clinics, and long-term care facilities. This pre-assembled kit combines a 14 Fr silicone-elastomer coated latex Foley catheter with a 2000 mL drain bag, delivering a complete sterile insertion system that emphasizes best practices and infection prevention.
This one-layer tray design creates an intuitive pathway through the catheterization process, minimizing contamination risk while ensuring all necessary components are organized and accessible. The silicone-elastomer coating on the latex catheter provides enhanced biocompatibility and resistance to encrustation and bacterial colonization, supporting extended catheter dwell time when clinically appropriate.
Catheter Specifications:
- French Size: 14 Fr with 10 mL balloon capacity
- Material: Silicone-elastomer coated latex for durability and biocompatibility
- Length: 16 inches (40.6 cm) standard adult sizing
- Tip Design: Straight tip with two opposing drainage eyes for optimal urine flow
- Model Type: 2-way catheter system
Drainage System Features:
- Drain Bag Capacity: 2000 mL with integrated collection chamber
- System Type: Closed sterile system to reduce contamination and infection risk
- Pre-Connection: Catheter is pre-connected to drain bag for seamless integration
- Anti-Reflux Design: Helps prevent backflow of urine into the bladder
Complete Kit Contents:
- Silicone-elastomer coated latex Foley catheter (14 Fr, 10 mL)
- 2000 mL drain bag with tubing
- Sterile vinyl examination gloves
- Water-soluble lubricating jelly for catheter insertion
- PVP swab sticks (3-pack) for patient cleansing and antiseptic preparation
- Pre-filled 10 mL sterile saline inflation syringe for balloon inflation
- Specimen collection container for urinalysis or culture
- Fenestrated sterile drape for field draping
- Underbuttocks moisture-proof drape for patient protection
- Skin prep pad (alcohol-based) for site preparation
- Foley catheter securement device to prevent migration and kinking
- Patient education card explaining catheter care and precautions
- Hand sanitizer packet for hygiene compliance
Specifications
| Catheter Included | Yes |
| Closed System | Yes |
| Coating | Silicone Elastomer |
| Drain Bag Capacity ML | 2000 ml |
| Drain Bag Included | Yes |
| Drainage Eye Type | Two Opposing Drainage Eyes |
| ERASE Cauti | Yes |
| French Size (FR) | 14 |
| Gloves | Yes |
| Length Inches | 16 " |
| Length in CM | 40.6 cm |
| Lube Jelly | Yes |
| Material | Latex |
| Model Type | 2 way |
| Patient Prep | PVP |
| Patient Type | Adult |
| Peri Care Wipe Included | No |
| Specimen Container | Yes |
| Pvp | Yes |
| Silver | No |
| Temperature Sensing | No |
| Tip Type | Straight |
| Volume ML | 10 mL |
| UNSPSC | 42142715 |
Warranty
- The product warranty is applicable as per the terms and conditions provided by the product manufacturer.
Please call us for specific details.
Return
- No returns will be accepted after 30 days from the date of shipment.
- All returns are subject to a restocking fee as per manufacturers terms and conditions.
- All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
- We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
- The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
- If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
- Hygiene, bath and toilet items cannot be returned once opened or used.
- Standard manufacturer terms and conditions apply for return policy of this product.
Please call us for specific details.
FAQs
Frequently Asked Questions:
What is included in the Medline One-Layer Foley Catheter Tray?
This comprehensive tray comes with a 14 Fr silicone-elastomer coated latex Foley catheter pre-connected to a 2,000 mL drain bag, plus all insertion components. You'll also receive vinyl gloves, lubricating jelly, PVP swabs, a pre-filled inflation syringe, specimen container, drapes, skin prep pads, a Foley securement device, and patient education materials for a complete closed sterile system.
Who should use this catheter tray, and is it suitable for long-term use?
This product is designed for adult patients requiring urinary catheterization in healthcare settings such as hospitals, clinics, and long-term care facilities. The silicone-elastomer coating helps resist encrustation and bacterial colonization, which can support longer catheter dwell time, though insertion protocols should follow your facility's clinical guidelines.
What does the 14 Fr size mean, and is this the right size for my patient?
French (Fr) is the unit of measurement for catheter diameter. A 14 Fr catheter is a common intermediate size for adult patients. The appropriate size depends on individual patient anatomy, gender, and clinical assessment. Healthcare providers should follow their facility's protocols and clinical judgment when selecting catheter size.
Is this product latex-free, and what should I know about latex allergies?
This catheter tray contains latex material and is not suitable for patients with documented latex allergies. If your patient has a known latex sensitivity or allergy, consult your supplier for alternative catheter options that are latex-free and specify this requirement when ordering.
What makes the silicone-elastomer coating beneficial?
The silicone-elastomer coating applied both internally and externally helps resist mineral encrustation and reduce bacterial colonization on the catheter surface. This can support improved biocompatibility and potentially reduce complications related to catheter obstruction and infection when used according to clinical best practices.
What is the drain bag capacity, and how often should it be emptied?
The included drain bag holds up to 2,000 mL of urine. Drainage bags should be emptied regularly to prevent backflow and maintain proper catheter function. Your facility's protocols and the patient's specific medical needs will determine the appropriate emptying schedule, typically when the bag reaches three-quarters full.














