McKesson Steam Sterilization Biological Indicator – Self-Contained Vial

Product Information

SKU:
MC73-SCS025-MI
Brand:
McKesson
MPN:
73-SCS025

McKesson Self-Contained Steam Biological Indicator

Paypal Pay later
Pay low as $3.22/month with Pay Pal's pay later service

Starts From

Current Price: $70.22
Original Price: $73.73
Savings: $3.51 OFF

Quantity

Select product quantity
Select Variant *Select an option To Add to Cart
Packaging:
2 more

McKesson Self-Contained Steam Biological Indicator Purchase Options

Auto Reorder Information

Save Dollars with Auto-Reorder!
Save Dollars with Auto Reorder! Get 5% OFF

Product Features and Policies

Description

McKesson Self-Contained Steam Biological Indicator is designed to monitor the effectiveness of steam sterilization processes with reliable and accurate performance. Inoculated with Geobacillus stearothermophilus spores, this indicator helps verify sterilizer efficacy across various steam sterilization cycles, ensuring compliance with standard sterilization validation protocols. It delivers a convenient final read-out in just 24 hours and fits existing incubators, making it suitable for hospitals, laboratories, and sterile processing environments.

Features:

  • Effective Sterilization Monitoring: Specifically designed to monitor saturated steam sterilization processes operating at 121°C–134°C, including gravity displacement, flash, and prevacuum cycles.
  • Validated Performance: Meets current USP and AAMI/ISO 11138 performance standards for steam sterilization indicators.
  • Fast Read-Out: Provides a final read-out result within 24 hours for quick sterilization verification.
  • Reliable Growth Media: Contains tryptic soy broth validated for growth promotion per USP guidelines, ensuring accurate results.
  • Versatile Compatibility: Works effectively in gravity and dynamic-air-removal (prevacuum) sterilization processes, with recommended adjustments for flash cycles.
  • Convenient Design: Fits existing incubators for easy integration into sterilization monitoring workflows.

Monitoring Frequency:

Per AAMI standards, Steam sterilizers should be biologically tested at least weekly, preferably daily and every load that contains an implant.

Instructions for Use:

  1. Record the sterilizer number, load number and processing date on the BI label.
  2. Place one or more BIs inside an instrument tray, rigid container, peel pouch or process challenge device, e.g. AAMI challenge pack, whichever is representative of the load being processed.
  3. Test the most challenging area in the sterilizer as indicated in the sterilizer’s instruction manual (i.e. the bottom shelf near the door, over the drain of a large sterilizer or in the middle shelf of a small sterilizer).
  4. Process the load according to the sterilizer manufacturer's instructions.
  5. Remove the BI and confirm the chemical indicator printed on the label has turned brown. Caution: After processing, the BI is hot and under pressure. Always allow to cool for ten (10) minutes before crushing. Failure to do so could cause the glass ampule inside the BI vial to burst which may result in injury. For this reason, safety glasses should be worn when handling and crushing a processed BI.

Activation and Incubation:

  1. Activate the processed BI within 8 hours after processing by gently crushing the inner glass media tube using a vial crusher.
  2. Incubate at 55 – 60°C for 24 hours checking for spore growth (visual color change from purple to yellow) at regular intervals (i.e. 3, 5 and 8 hours). Growth of surviving spores has been documented in as little as 2 1/2 hours.

Test Results:

  1. Record negative (no growth) results after full incubation in a Sterilizer Record Notebook. No color change in the purple media indicates proper sterilization.
  2. Any positive (growth indicated by purple to yellow color change) result, should be reported immediately to a Supervisor and the sterilizer taken out of service until resolved.
  3. The stability of positive growth as indicated by a yellow color change has been tested up to 48 hours.

Use of Controls:

As a control, an unprocessed BI (from the same lot) should be gently crushed using a vial crusher and incubated each day the sterilizer is tested

Details

Sizing/specifications
Manufacturer McKesson
Application Sterilization Biological Indicator Vial
Sterilization Compatibility Steam
Temperature Range 140°F (60°C)
Time to Results 24-Hour Processing Time
UNSPSC Code 42281803

Details

Warranty
  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

Details

Return policy
  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.

Looking for more information?

Opens a form to submit your question to the community

Unanswered Questions

    Questions and Answers

    Customer Reviews

    Select Variant

    McKesson Self-Contained Steam Biological Indicator

    Price information$70.22$73.73
    Product Options

    Product Configuration Options

    Select Packaging option

    Select Packaging :

    Select Group

    Group Product Options

    Additional Content

    Product Details