Company Logo
MIC Gastrostomy Feeding Tube With Enfit Connectors, 14 Fr - Each - Image 1
Image 1 of 1. Swipe to navigate. Tap to view fullscreen.

MIC Gastrostomy Feeding Tube With Enfit Connectors, 14 Fr - Each

4.0(1)
🔥 7+ people bought this recently
SKU:AV8100-12LV-MI : AV8100-14LV
MPN:8100-14LV
GTIN:10680651442915
UOM:Each
Each

Earn Loyalty Points

+63

Buy more to unlock extra rewards!

PayPal Pay Later

Pay low as $2.86/month with Pay Pal's pay later
$62.43
$65.55Save $3.12
Subscribe & Save
Save 5%
$59.31$62.43
Secure transaction
Your payment information is processed securely.
Latex Free
Latex Free
Sterile Product
Sterile Product
Free Shipping Over $100
Free Shipping Over $100

Description

MIC Gastrostomy Feeding Tubes are designed for patients requiring long-term enteral nutrition who cannot tolerate oral intake, have a low aspiration risk, or need gastric decompression or medication delivery directly into the stomach. These tubes may be placed surgically, percutaneously under fluoroscopic or endoscopic guidance, or used as a replacement when a mature stoma tract already exists.

Features

  • Gamma sterilized for safety.
  • Material: Soft, medical-grade silicone.
  • Universal enteral feeding port connector.
  • Dedicated medication port for easy dosing.
  • Recessed distal tip for comfortable insertion.
  • Radiopaque stripe for enhanced visibility during imaging.
  • SECUR-LOK external retention ring for secure positioning.
  • Inflatable silicone retention balloon to help maintain placement.

Indications for Use

The Avanos MIC gastrostomy feeding tubes are intended for patients who require long-term enteral feeding, cannot tolerate oral intake, are at low risk for aspiration, or need gastric decompression or medication delivery directly into the stomach.

Contraindications

Contraindications include colonic interposition, ascites, portal hypertension, peritonitis, uncorrected coagulopathy, infection around the stoma site, and absence of an established tract for replacement.

Complications

Possible complications include nausea, vomiting, abdominal bloating, aspiration, skin breakdown, infection, hypergranulation tissue, tube clogging, leakage, balloon failure, and device dislodgement.

Placement

MIC gastrostomy feeding tubes may be placed surgically, percutaneously under fluoroscopic or endoscopic guidance, or as a replacement using an existing stoma tract.

Warning: Perform gastropexy to secure the stomach to the abdominal wall and identify the insertion site prior to tube insertion. Do not use the retention balloon for gastropexy.

Balloon Maintenance

Balloon life varies based on care and patient factors. Check balloon water volume weekly using sterile or distilled water only. Replace the tube if balloon leakage or rupture is detected.

Daily Care & Maintenance Check List

  • Inspect stoma site and tube condition daily.
  • Clean using warm water and mild soap; rinse and dry thoroughly.
  • Rotate tube daily and ensure external bolster rests 1–2 mm above the skin.
  • Flush regularly based on facility guidelines.

MRI Safety Information

MIC gastrostomy feeding tubes are MR Safe.

Warning

Do not reuse, reprocess, or resterilize this medical device. Reuse, reprocessing, or resterilization may

  • For enteral nutrition and/or enteral medication only
  • Adversely affect the known biocompatibility characteristics of the device
  • Compromise the structural integrity of the device
  • Lead to the device not performing as intended, or
  • Create a risk of contamination and cause the transmission of infectious diseases resulting in patient injury, illness, or death.

Specifications

Brand MIC
Manufacturer Avanos Medical
Application Gastrostomy Feeding Tube with ENFit Connector
Material Silicone
Sterility Sterile
ENFit Connector Yes
Feed Set Connector Type ENFit
Jejunal Feeding Port No
Medication Port Yes
Radiopaque Stripe Yes
Sterile True
Sterilization Method Gamma
Tube Tip Type Recessed Distal Tip

Warranty

  • The product warranty is applicable as per the terms and conditions provided by the product manufacturer.

Please call us for specific details.

Return

  • No returns will be accepted after 30 days from the date of shipment.
  • All returns are subject to a restocking fee as per manufacturers terms and conditions.
  • All returns must have an RGA number (Returned Goods Authorization), unauthorized returns will not be accepted.
  • We do not guarantee fulfillment of any desired purpose or product suitability to the user and this will not be considered as a valid reason for return.
  • The products must be new, unused condition, not tampered with, in original packaging and returned at the customers expense in the original packaging.
  • If your return is not due to any manufacturing defect then the original shipping cost will be deducted from the total refund.
  • Hygiene, bath and toilet items cannot be returned once opened or used.
  • Standard manufacturer terms and conditions apply for return policy of this product.

Please call us for specific details.